# UpStation network UPS-DSN-20261103-G9YQ — budgetary design, not a quote

Prepared 2026-11-03 for **Example AI Lab** · Head of ML Infrastructure · prices as of 2026-11-03

## 4× HGX B300 training cluster (32 GPUs) with NVMe storage and a services cluster, Montana colo

```mermaid
flowchart TB
  GF["GPU fabric: 1× 32× 800G OSFP<br/>800G 1:1, 32 links"]
  GN["4× 8x NVIDIA B300 (HGX B300 NVL8)"] -- "32× 800G" --> GF
  FE["Front-end MLAG pair: 2× 32× 400G QSFP-DD<br/>400G, storage converged"]
  GN -- "2× 400G per node" --> FE
  SN["5× 2U all-NVMe storage node"] -- "2× 100G per node" --> FE
  MG["3× cluster services node"] -- "2 ports per node" --> FE
  FE -. "uplinks to your core (not priced)" .-> CORE(("Your network"))
  OOB["OOB: 1× 1G switch"] -. "BMC, 15 ports" .- GN
```

## Fabrics

| Fabric | Speed | Switches | Ports used / total | Oversubscription |
|---|---|---|---|---|
| gpu fabric | 800G | 1× 32× 800G OSFP | 32 / 32 | 1:1 |
| front end | 400G | 2× 32× 400G QSFP-DD | 18 / 64 | 3:1 or better |
| oob | 1G | 1× 48× 1G RJ45 + 4× 10G | 15 / 48 | n/a |

## How it was designed

- GPU fabric: 32 × 800G ports (1 per GPU) ≤ 32 → one 32× 800G OSFP switch, 1:1 non-blocking (single point of failure; a leaf-spine removes it).
- Front-end: 2 ports per host, one to each switch of an MLAG pair of 32× 400G QSFP-DD switches; 7 ports per switch of 30 usable → 1 pair(s). Storage stays converged on this plane (well under 40 GB/s per node).
- OOB: 12 hosts + 3 switches = 15 × 1G ports → 1 × 48× 1G RJ45 + 4× 10G.

## Network bill of materials

| Item | Qty | Unit (USD) | Extended |
|---|---|---|---|
| 32× 800G OSFP switch (GPU fabric) | 1 | $37,500.00 | $37,500.00 |
| 800G link: 2× SR8 + 2× MTP-12 OM4 10 m — node to leaf, 1 per GPU port (estimated optical) | 32 | $2,058.00 | $65,856.00 |
| 32× 400G QSFP-DD switch (front-end pair, MLAG) | 2 | $20,000.00 | $40,000.00 |
| +2× 400G north-south (budgeted at the Supermicro equivalent option; Aivres fits its own 400G NICs and confirms them on its quote) (listed option, one per GPU node) | 4 | $2,693.94 | $10,775.76 |
| 400G AOC 10 m — GPU nodes to the pair, 2 per node | 8 | $1,055.00 | $8,440.00 |
| 400G→4×100G breakout 2 m — storage nodes to the pair (4 nodes per cable) | 4 | $199.00 | $796.00 |
| 400G→4×100G breakout 2 m — cluster services nodes to the pair (4 nodes per cable) | 2 | $199.00 | $398.00 |
| 400G 2 m passive DAC — peer link | 2 | $174.00 | $348.00 |
| 48× 1G RJ45 + 4× 10G switch (OOB) | 1 | $989.00 | $989.00 |
| Cat6 patch — 1G BMC/management (not priced) | 15 | $0.00 | $0.00 |
| **Network total** | | | **$165,102.76** |

## Port map and cable schedule (63 cables, 73 connections)

Rows that share a cable ID are lanes of one breakout cable. Device names match the rack elevation.

| Cable | Fabric | From | To | Cable type |
|---|---|---|---|---|
| C0001 | gpu fabric | gpu-01:GPU NIC 1 | gpu-sw-1:1 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0002 | gpu fabric | gpu-01:GPU NIC 2 | gpu-sw-1:2 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0003 | gpu fabric | gpu-01:GPU NIC 3 | gpu-sw-1:3 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0004 | gpu fabric | gpu-01:GPU NIC 4 | gpu-sw-1:4 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0005 | gpu fabric | gpu-01:GPU NIC 5 | gpu-sw-1:5 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0006 | gpu fabric | gpu-01:GPU NIC 6 | gpu-sw-1:6 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0007 | gpu fabric | gpu-01:GPU NIC 7 | gpu-sw-1:7 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0008 | gpu fabric | gpu-01:GPU NIC 8 | gpu-sw-1:8 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0009 | gpu fabric | gpu-02:GPU NIC 1 | gpu-sw-1:9 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0010 | gpu fabric | gpu-02:GPU NIC 2 | gpu-sw-1:10 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0011 | gpu fabric | gpu-02:GPU NIC 3 | gpu-sw-1:11 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0012 | gpu fabric | gpu-02:GPU NIC 4 | gpu-sw-1:12 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0013 | gpu fabric | gpu-02:GPU NIC 5 | gpu-sw-1:13 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0014 | gpu fabric | gpu-02:GPU NIC 6 | gpu-sw-1:14 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0015 | gpu fabric | gpu-02:GPU NIC 7 | gpu-sw-1:15 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0016 | gpu fabric | gpu-02:GPU NIC 8 | gpu-sw-1:16 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0017 | gpu fabric | gpu-03:GPU NIC 1 | gpu-sw-1:17 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0018 | gpu fabric | gpu-03:GPU NIC 2 | gpu-sw-1:18 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0019 | gpu fabric | gpu-03:GPU NIC 3 | gpu-sw-1:19 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0020 | gpu fabric | gpu-03:GPU NIC 4 | gpu-sw-1:20 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0021 | gpu fabric | gpu-03:GPU NIC 5 | gpu-sw-1:21 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0022 | gpu fabric | gpu-03:GPU NIC 6 | gpu-sw-1:22 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0023 | gpu fabric | gpu-03:GPU NIC 7 | gpu-sw-1:23 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0024 | gpu fabric | gpu-03:GPU NIC 8 | gpu-sw-1:24 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0025 | gpu fabric | gpu-04:GPU NIC 1 | gpu-sw-1:25 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0026 | gpu fabric | gpu-04:GPU NIC 2 | gpu-sw-1:26 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0027 | gpu fabric | gpu-04:GPU NIC 3 | gpu-sw-1:27 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0028 | gpu fabric | gpu-04:GPU NIC 4 | gpu-sw-1:28 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0029 | gpu fabric | gpu-04:GPU NIC 5 | gpu-sw-1:29 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0030 | gpu fabric | gpu-04:GPU NIC 6 | gpu-sw-1:30 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0031 | gpu fabric | gpu-04:GPU NIC 7 | gpu-sw-1:31 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0032 | gpu fabric | gpu-04:GPU NIC 8 | gpu-sw-1:32 | 800G link: 2× SR8 + 2× MTP-12 OM4 10 m |
| C0033 | front end | gpu-01:FE 1 | fe-1a:1 | 400G AOC 10 m |
| C0034 | front end | gpu-01:FE 2 | fe-1b:1 | 400G AOC 10 m |
| C0035 | front end | gpu-02:FE 1 | fe-1a:2 | 400G AOC 10 m |
| C0036 | front end | gpu-02:FE 2 | fe-1b:2 | 400G AOC 10 m |
| C0037 | front end | gpu-03:FE 1 | fe-1a:3 | 400G AOC 10 m |
| C0038 | front end | gpu-03:FE 2 | fe-1b:3 | 400G AOC 10 m |
| C0039 | front end | gpu-04:FE 1 | fe-1a:4 | 400G AOC 10 m |
| C0040 | front end | gpu-04:FE 2 | fe-1b:4 | 400G AOC 10 m |
| C0041 | front end | stor-01:FE 1 | fe-1a:5/1 | 400G→4×100G breakout 2 m |
| C0042 | front end | stor-01:FE 2 | fe-1b:5/1 | 400G→4×100G breakout 2 m |
| C0041 | front end | stor-02:FE 1 | fe-1a:5/2 | 400G→4×100G breakout 2 m |
| C0042 | front end | stor-02:FE 2 | fe-1b:5/2 | 400G→4×100G breakout 2 m |
| C0041 | front end | stor-03:FE 1 | fe-1a:5/3 | 400G→4×100G breakout 2 m |
| C0042 | front end | stor-03:FE 2 | fe-1b:5/3 | 400G→4×100G breakout 2 m |
| C0041 | front end | stor-04:FE 1 | fe-1a:5/4 | 400G→4×100G breakout 2 m |
| C0042 | front end | stor-04:FE 2 | fe-1b:5/4 | 400G→4×100G breakout 2 m |
| C0043 | front end | stor-05:FE 1 | fe-1a:6/1 | 400G→4×100G breakout 2 m |
| C0044 | front end | stor-05:FE 2 | fe-1b:6/1 | 400G→4×100G breakout 2 m |
| C0045 | front end | svc-01:FE 1 | fe-1a:7/1 | 400G→4×100G breakout 2 m |
| C0046 | front end | svc-01:FE 2 | fe-1b:7/1 | 400G→4×100G breakout 2 m |
| C0045 | front end | svc-02:FE 1 | fe-1a:7/2 | 400G→4×100G breakout 2 m |
| C0046 | front end | svc-02:FE 2 | fe-1b:7/2 | 400G→4×100G breakout 2 m |
| C0045 | front end | svc-03:FE 1 | fe-1a:7/3 | 400G→4×100G breakout 2 m |
| C0046 | front end | svc-03:FE 2 | fe-1b:7/3 | 400G→4×100G breakout 2 m |
| C0047 | front end | fe-1a:31 | fe-1b:31 | 400G 2 m passive DAC |
| C0048 | front end | fe-1a:32 | fe-1b:32 | 400G 2 m passive DAC |
| C0049 | oob | gpu-01:BMC | oob-1:1 | Cat6 patch |
| C0050 | oob | gpu-02:BMC | oob-1:2 | Cat6 patch |
| C0051 | oob | gpu-03:BMC | oob-1:3 | Cat6 patch |
| C0052 | oob | gpu-04:BMC | oob-1:4 | Cat6 patch |
| C0053 | oob | stor-01:BMC | oob-1:5 | Cat6 patch |
| C0054 | oob | stor-02:BMC | oob-1:6 | Cat6 patch |
| C0055 | oob | stor-03:BMC | oob-1:7 | Cat6 patch |
| C0056 | oob | stor-04:BMC | oob-1:8 | Cat6 patch |
| C0057 | oob | stor-05:BMC | oob-1:9 | Cat6 patch |
| C0058 | oob | svc-01:BMC | oob-1:10 | Cat6 patch |
| C0059 | oob | svc-02:BMC | oob-1:11 | Cat6 patch |
| C0060 | oob | svc-03:BMC | oob-1:12 | Cat6 patch |
| C0061 | oob | gpu-sw-1:mgmt | oob-1:13 | Cat6 patch |
| C0062 | oob | fe-1a:mgmt | oob-1:14 | Cat6 patch |
| C0063 | oob | fe-1b:mgmt | oob-1:15 | Cat6 patch |

## Assumptions

- None beyond the catalog conventions.

**Next step.** Book the intro (https://calendly.com/alecglover/intro-call) or email alec@upstation.io with the design ID; UpStation validates the design and introduces the supplier that fits.

Prepared by UpStation from public supplier prices at ai.upstation.io. Budgetary only; the supplier confirms price, availability and lead time on order. UpStation does not resell. alec@upstation.io